Gallons per Minute at Discharge Height Above Pumping level |
10" | 20" | 30" | 40" | 50" | 60" |
108 GPM | 98 GPM | 86 GPM | 71 GPM | 47 GPM | - |
NOTE: Table shows approximate Head-Flow for new pump.
• DESIGN: Pumps are rated for continuous use. Featuring clog-resistant, semi-open metallic impellers. Discharge port can be rotated at 90-degree intervals. Pumps feature maintenance-free ball bearings.
• VISCOSITY and SPECIFIC GRAVITY: Standard pump models (at 3450 RPM) will handle viscosity to 100 SSU (at 1.1 specific gravity or less) and up to 200 SSU (specific gravity of 1.0 or less). For viscosity up to 400 SSU (specific gravity of 1.0 or less), increase motor HP by one size.
• PRESSURES: Maximum Pump performance up to 58 Feet TDH. Maximum casing working pressure is 200 PSI.
• TEMPERATURES: Recommended for liquid temperatures up to 200°F
USES :
Shertech close-coupled cast iron, bronze or 316 stainless steel units pump continuously, producing high flow rates under lowhead conditions. Designed for continuous low-pressure circulation and transfer of non-flammable liquids, utility, boiler feed, general transfer, filtration, cooling towers, condensate return, marine applications, fountains, boosters, water circulation, irrigation, spraying systems, jockey pump service, chemical processing, aggressive liquid applications and other generalpurpose pumping compatible with pump component materials where no suction lift or no self-priming is required.
NOTICE :
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres. When pumping hazardous or dangerous materials, use only in room or area designated for that purpose. For your protection, always wear proper clothing, eye protection, etc. in case of any malfunction. For proper handling techniques and cautions, contact your chemical supplier, insurance company and local agencies (fire dept., etc.). Failure to comply with this warning could result in personal injury and/or property damage.