Little Giant # MS900-6B Submersible Marine Pump

Little Giant Pump MS900-6B

Little Giant # MS900-6B

Little Giant catalog # MS900-6B, Submersible Marine Pump, Dual purpose for Submersible or in-line use, rated for 900 GPH gallons per hour at 1 foot of head open flow. Motor is 115 Volts, Single Phase. Motor has a 6 foot cord. Inlet Port is 3/4 inch MNPT and 1 inch hose, Discharge Port is 1/2 inch MNPT and 3/4 inch hose.

Price : $ 415.50

Qty :

5 Days (direct from Little Giant)

 

Product Information :

The Little Giant MS900-6B is a Submersible Marine Pump, Dual purpose for Submersible or in-line use, rated for 900 GPH gallons per hour at 1 foot of head open flow, with a 3/4 inch MNPT and 1 inch hose inlet port by 1/2 inch MNPT and 3/4 inch hose outlet port, coupled to a 115 Volt, single phase Motor that has a 6 foot cord. This stainless steel and bronze pump is meant to be used submerged or inline with a flooded suction. It is intended to circulate fresh or saltwater through marine air conditioner heat exchanger coils and is extremely quiet in operation. It includes a sturdy mounting bracket for securing the pump in position and holding it in place. This pump is not self-priming and must be located below the waterline. Seawater enters low and exits high. This pump is made of premium stainless steel and bronze construction for added longevity. This pump features a flow adjuster. It is generally used in marine air-conditioning applications and is UL and CSA listed for consumer confidence. It is Dual-purpose - for submersible or inline below water level, and can be used in fresh, salt, chlorinated, or brominated water. It has Non-corrosive stainless steel/bronze construction for longevity, and a tinned 6 foot power cord for marine applications. It can be used in hot water applications up to 110 degrees F (43.4 degrees C). The pump's body construction is Stainless steel/bronze, with a Nylon volute and Nylon impeller This pump uses two Viton shaft seals, a 1/2 inch barbed hose adapter, a 1/40 HP motor, thermal protections, a 3/8 inch FNPT intake, and a 1/4 inch MNPT discharge. It can pump liquids with a maximum temperature of 120 F
WEIGHT : The Little Giant MS900-6B weighs 10 Lbs.

Features :

Port Size:
Inlet Port is 3/4 inch MNPT and 1 inch hose, Discharge Port is 1/2 inch MNPT and 3/4 inch hose.
Motor Specs :
115 Volts, Single Phase. that has a 6 foot cord.

Applications

There are many applications that the Little Giant MS9006B are used in. Typical applications for this pump include Submersible, water transfer or recirculation, water displays, air conditioners, machine tool coolants, and mild acids. It is suitable for fresh, salt, chlorinated or brominated water max 35 ppm

To install, connect the strainer to the pump inlet. Ensure accessibility for future maintenance. Both pump and strainer must be mounted within 2 feet of the throughhull. IMPORTANT Do not connect the pump to the engine water cooling intake as this can cause the engine to run dry. Connect the seacock and strainer. Secure every connection with stainless steel clamps. NOTE The throughhull and the seacock must be installed at least 812 inches below the water line. Connect the pump discharge to the air conditioner. This pump is ignitionprotected and must be within 10 feet of the air conditioner. IMPORTANT Do not cut hose until it is positioned in its final location. Attach the bracket to the pump and mount the assembly horizontally in a stable, flat place in the bilge. For power boats ensure the pump always sits below the water line, even during hydroplaning. For sail boats mount the pump close to the centerline to avoid losing water intake when heeling. NOTE The discharge must always sit above the inlet. NOTE Always orient the volute so that the inlet remains closest to the strainer and the discharge closest to the A/C. Position the throughhull water return line as close to the pump as possible and 48 inches above the water. Employ an electrician to do the wiring. Connect the power cord to a constant source of power matching the pump nameplate voltage. The pump should be connected or wired to its own circuit, with no other equipment in the circuit. Do not connect to a fan or any device that runs intermittently. The fuses or circuit breaker should be of ample capacity. Connect to a circuit equipped with a ground fault circuit interrupter GFCI if required by code. Do not splice into the pump power cord. If necessary to add additional cord length, use a sealed junction box to splice marine grade cable to existing pump cable. Do not remove the existing cable supplied with the pump. IMPORTANT If the power cord is damaged, the whole unit must be replaced. Periodically observe the pumps performance. If a decrease in flow is noted, clean the pump as follows Disconnect pump from power and remove from water source. Unscrew the pump housing from the pump body. IMPORTANT Do not open the motor housing. Carefully clean any debris from the impeller and pump housing